PRODUCT CATALOG

Cardiac Rhythm Management | Connectivity and Remote Care | Connectivity

Merlin® Pacing System Analyzer (PSA)

Product Highlights

  • Provides confidence and control at implant by quickly delivering accurate measurements for optimal lead positioning and a streamlined implant.
  • Connects directly to the Merlin® Patient Care System, delivering a seamless, intuitive interface.
  • Fast parameter programming and witching speed.
  • Able to display on external monitors.
  • Independent atrial, right ventricular and left ventricular channels.
  • Continuously displayed measurements on a beat-by-beat basis.
  • Dedicated current of injury display.
Merlin®


Ordering Information

Reorder Number Part Number Description
EX3100 100002300 Merlin Pacing System Analyzer

Merlin PSA accessories

Reorder Number Part Number Description
EX3160 100031916 Merlin storable pouch
EX3170 100015290 For use with Medtronic-style disposable cables (Models 4051 and 4061)
EX3180 100015301 For use with Medtronic 2292 re-sterilizable cable
EX3190 100019848 USB to RF antenna
4051 1020752-001 Disposable Threshold Cable (Medtronic connector)
4053A 5070142-101 Non-Disposable Adapter (to threshold cable Medtronic connector)
4160 60010198-001 Disposable Threshold cable for DF4 leads (Biotronik connector)
4161 60010086-001 Disposable Threshold cable for DF4 leads (Medtronic connector)

CAUTION: FEDERAL LAW (USA) RESTRICTS THIS DEVICE TO SALE, DISTRIBUTION AND USE BY OR ON THE ORDER OF A PHYSICIAN.

Brief Summary: Prior to using these devices, please review the User’s Manual for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use.

Intended Use: The Merlin® PSA is intended to assess the pacing and sensing performance of the lead system prior to pulse generator implantation, or during invasive lead system troubleshooting.

Only use the Merlin PSA with the Merlin PCS.

Contraindications: There are no known contraindications to the use of a lead-analysis device. The patient’s age and medical condition, however, may dictate the pacing modes and lead assessment activities appropriate for the patient.

The Merlin PSA is not intended for use as a temporary pacemaker or for life sustaining pacing support.

The Merlin PSA is not intended for diagnostic purposes.