PRODUCT CATALOG

Cardiac Rhythm Management | Implant Tools | CRT Lead Delivery Tools (Implant Tools for United States)

CPS Aim® SL

Slittable Inner Catheter with Integrated Valve

Product Highlights

  • A family of slittable inner catheters with integrated valve designed to assist with coronary sinus cannulation, branch vein subselection and left-heart lead delivery.
  • Three CPS Aim® SL inner catheters enable atraumatic subselection and Direct-to-Target™ lead placement.
  • A combination of PEBAX® material that becomes softer from the proximal to the distal end and increased braid wire at the distal end provide for a torqueable, kink-resistant and soft-tipped subselector.
  • Two CPS Aim® cannulators assist with coronary sinus access.
  • The catheter body and tip are clearly seen under fluoroscopy.
CPS Aim® SL


Ordering Information

Contents: Slittable inner catheter

Reorder Number Curve Length (cm) Working Length (cm) Overall Diameter (F) Inner Diameter (F) Outer
DS2N021-59 Acute 59 62 5 7
DS2N021-65 Acute 65 68 5 7
DS2N022-59 90º 59 62 5 7
DS2N022-65 90º 65 68 5 7
DS2N023-59 Obtuse 59 62 5 7
DS2N023-65 Obtuse 65 68 5 7
DS2N024-65 CSL 65 68 5 7
DS2N025-65 ALII 65 68 5 7

CAUTION: FEDERAL LAW (USA) RESTRICTS THIS DEVICE TO SALE, DISTRIBUTION AND USE BY OR ON THE ORDER OF A PHYSICIAN.

Brief Summary: Prior to using these devices, please review the User’s Manual for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use.

Indications: The St. Jude Medical CPS Aim® SL slittable inner catheter (subselector/cannulator) is designed for intracardiac access of the coronary sinus and subselection of the venous system of the heart, and to serve as a conduit during implantation for the delivery of contrast medium and St. Jude Medical devices, including guidewires. In addition, CPS Aim SL slittable inner catheters (subselector/cannulator) can work with outer guide catheters as a system.

Potential Adverse Events: As with any catheterization procedure, potential complications include thromboembolism, local and systemic infection, bleeding or hematoma at the puncture site, vascular dissection or perforation, cardiac perforation, and cardiac tamponade.

Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use.