PRODUCT CATALOG

Electrophysiology | Therapy | Standard Ablation Catheters

Therapy™ Bi-directional Ablation Catheters
4 mm Tip Thermocouple

Quadripolar
7 F

Product Highlights

  • Symmetrical bi-directional steering
  • Thermocouple temperature measurement
  • Push/pull handle


Ordering Information

Contents: 7 F Ablation Catheter (1 unit per box)

Reorder Number Description Electrode Spacing (mm) Tip Electrode (mm) Band Electrode (mm) Curve Type Usable Length (cm)
IBI-83719 1304-7-25-M-BD 2-5-2 4 2 Medium 110
IBI-83720 1304-7-25-L-BD 2-5-2 4 2 Large 110

Required Catheter Connecting Cables

Reorder Number Compatible Generator
IBI-85641 SJM
IBI-85713 Stockert
IBI-85711 Medtronic
Therapy™ Bi-directional Ablation Catheters 4 mm Tip Thermocouple


Rx Only

Brief Summary: Please review the Instructions for Use prior to using these devices for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use.

INDICATIONS

The Therapy™ Cardiac Ablation System is indicated for mapping and for use with a compatible RF generator for: interruption of accessory atrioventricular (AV) conduction pathways associated with tachycardia; the treatment of AV nodal re-entrant tachycardia (AVNRT); or creation of complete AV nodal block in patients with a difficult to control ventricular response to an atrial arrhythmia.

CONTRAINDICATIONS

In patients with active systemic infection. In patients with intracardiac mural thrombus, ventriculotomy or atriotomy within the preceding four weeks.

WARNINGS

Catheter ablation procedures present the potential for significant x-ray exposure. The long-term risk of protracted fluoroscopy has not been established. Careful consideration must be given for the use of the device in prepubescent children and pregnant women. The long term risks of RF ablation lesions have not been established. Patients undergoing AV nodal modification or ablation of septal accessory pathways are at risk for inadvertent AV block.

PRECAUTIONS

Appropriate DIP pads should be used to minimize skin burns.

POTENTIAL ADVERSE EVENTS

Potential adverse events include, but are not limited to, cardiovascular and anesthesia-related complications, including complete heart block requiring pacemaker. Please refer to the Instructions for Use for a complete list.

 

Unless otherwise noted, ™ indicates that the name is a trademark of, or licensed to, St. Jude Medical or one of its subsidiaries. ST. JUDE MEDICAL and the nine-squares symbol are trademarks and service marks of St. Jude Medical, Inc. and its related companies.

©2018 St. Jude Medical, Inc. All rights reserved.

SJM-CAG-0915-0035t(1)

Customer Support: 855-478-5833

Last Updated: March 28, 2018