Masters Series Mechanical Heart Valve Standard Cuff

Product Highlights

  • Pyrolytic carbon leaflets and orifice ring offer exceptional durability and increased thromboresistance1
  • 85 degree leaflet opening angle offers improved laminar flow and reduces turbulence2-4
  • Controlled torque rotation mechanism allows for easy rotation and intraoperative adjustment
  • The expanded Masters aortic cuff has approximately 25% more cuffthan the standard cuff
  • St. Jude Medical heart valves are MR conditional5
Masters Series Mechanical Heart Valve Standard Cuff


Ordering Information

Contents: Aortic Valve (1 unit per box)

Reorder Number Tissue Annulus Diameter (mm) Valve Orifice Inner Diameter (mm) Geometric Orifice Area (cm2) Effective Orifice Area (cm2)6 Cuff Style
19AJ-501 19 14.8 1.63 1.16 Standard
21AJ-501 21 16.7 2.06 1.51 Standard
23AJ-501 23 18.6 2.55 2.03 Standard
25AJ-501 25 20.4 3.09 2.59 Standard
27AJ-501 27 22.5 3.67 3.08 Standard
29AJ-501 29 24.2 4.41 Not reported Standard
31AJ-501 31 26.1 5.18 Not reported Standard

1. Emery RW, Krogh CC, Arom KV, et al. The St. Jude Medical cardiac valve prosthesis: A 25-year experience with single valve replacement. Ann Thorac Surg. 2005;79:776-83.

2. King, M, David T, Fisher J. An initial parametric study on fluid flow through bileaflet mechanical heart valves using computational fluid dynamics. J Eng Med 1994: 208:63-72.

3. Feng Z, Nakamura T, Fujimoto T, et al. In vitro investigation of opening behavior and hydrodynamics of bileaflet valves in the mitral position. Artificial Organs 2002;26(1):32-9.

4. Shipkowitz T, Ambrus J, Kurk J, et al. Evaluation technique for bileaflet mechanical valves. J Heart Valve Dis. 2002, Mar; 11 (2):275-82.

5. St. Jude Medical MRI Safety Document.


6. Walker DK, Brendzel AM, Scotten LN. The New St. Jude Medical Regent mechanical heart valve: Laboratory measurements of hydrodynamic performance. J Heart Valve Dis. 1999;8(6):687-96.

Rx Only

St. Jude Medical prosthetic heart valves are indicated for use as replacement valves in patients with a diseased, damaged, or malfunctioning native or prosthetic valve. Possible side effects for all valvular implants include, but are not limited to: regurgitation, thromboembolic phenomena, resistance to flow, infection, hemolysis, dysrhythmias, and prosthetic dehiscence or failure. Anticoagulation is recommended for patients with mechanical valve implants. Please see the physician’s manual for a full description of indications, contraindications, side effects, precautions, warnings and instructions for use.

Unless otherwise noted, ™ indicates that the name is a trademark of, or licensed to, St. Jude Medical or one of its subsidiaries. ST. JUDE MEDICAL and the nine-squares symbol are trademarks and service marks of St. Jude Medical, Inc. and its related companies.

©2018 St. Jude Medical, Inc. All rights reserved.

100033292 – May 2012

Customer Support: 855-478-5833

Last Updated: April 19, 2013